INTERNATIONAL JOURNAL OF NOVEL RESEARCH AND DEVELOPMENT International Peer Reviewed & Refereed Journals, Open Access Journal ISSN Approved Journal No: 2456-4184 | Impact factor: 8.76 | ESTD Year: 2016
Scholarly open access journals, Peer-reviewed, and Refereed Journals, Impact factor 8.76 (Calculate by google scholar and Semantic Scholar | AI-Powered Research Tool) , Multidisciplinary, Monthly, Indexing in all major database & Metadata, Citation Generator, Digital Object Identifier(DOI)
Today the use of power electronic devices has increased manifold. Mostly power electronics devices are nonlinear in nature. Harmonics are defined as sinusoidal waveforms having frequencies that are integer multiples of the fundamental frequency (50 or 60 Hz); they may be voltages or currents. The main sources of harmonic sources are power semiconductor devices, electric furnaces, fluorescent lamps, rotating machines, saturated devices like transformer, variable frequency drives (VFDs) in modern industry. High-order harmonics tend to be aggravated by the high-frequency switching operation of power converters, which may trigger the parallel and series resonance in the power system [1]. The processes of cement industry and textile industry with excessive use of nonlinear loads have an impact on the power quality at the connected electric network. Harmonic distortion is one of the most significant phenomena that affect the plant distribution network as well as grid performance. Adjustable speed drives are devices that are used by both paper making machines and ventilators. The processes of cement industry and textile industry with excessive use of nonlinear loads have an impact on the power quality at the connected electric network. Harmonic distortion is one of the most significant phenomena that affect the plant distribution network as well as grid performance. Adjustable speed drives are devices that are used by both paper making machines and ventilators. In this paper, two test systems of IEEE 6 bus system with VFDs and IEEE 9 bus system with VFDs have been used to harmonic analysis. To study the total harmonic distortion produced by ASDs, these have been simulated on two standard test systems, IEEE 6 by system and IEEE 9 bus system with the help of ETAP software
Keywords:
Harmonic analysis, Total harmonic distortion, IEEE 6 Bus system, IEEE 9 Bus system, Variable frequency drive, Adjustable frequency drive
Cite Article:
"AN OVERVIEW OF HARMONIC ANAYSIS DUE TO VARIABLE FREQUENCY DRIVE AND MITIGATION TECHNIQUE", International Journal of Novel Research and Development (www.ijnrd.org), ISSN:2456-4184, Vol.8, Issue 4, page no.b523-b538, April-2023, Available :http://www.ijnrd.org/papers/IJNRD2304163.pdf
Downloads:
000118754
ISSN:
2456-4184 | IMPACT FACTOR: 8.76 Calculated By Google Scholar| ESTD YEAR: 2016
An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 8.76 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator
Facebook Twitter Instagram LinkedIn