INTERNATIONAL JOURNAL OF NOVEL RESEARCH AND DEVELOPMENT International Peer Reviewed & Refereed Journals, Open Access Journal ISSN Approved Journal No: 2456-4184 | Impact factor: 8.76 | ESTD Year: 2016
Scholarly open access journals, Peer-reviewed, and Refereed Journals, Impact factor 8.76 (Calculate by google scholar and Semantic Scholar | AI-Powered Research Tool) , Multidisciplinary, Monthly, Indexing in all major database & Metadata, Citation Generator, Digital Object Identifier(DOI)
Air pollution is now considered to be the world’s largest environmental health threat, accounting for 7 million deaths around the world every year. The main substances affecting health are: nitrogen oxides (NOx), sulphur oxides (SOx), ozone and particulate matter with the latter – especially particulate matter below 2.5 microns (PM 2.5) – being of greatest concern, as these tiny particles penetrate deep into the lungs, affecting both the respiratory and vascular systems. Both extent and duration of the exposure influence health outcomes. Major reason of air pollution is Industrial Emission from various industries like Cement plant, Power Sector Still division Paper Mills etc. Emission from industries can be minimized by using ESP. But time to time its maintenance and non availability of ESP field, causes either stack emission above permissible value or minimize the production. This paper presents the research that how availability of ESP can be increased and the stack emission can be reduced even in case of one or two field failure. For 90TPH boiler whose flue gas flow was 40m3/sec need three ESP field, which has been studied and exactly same two new ESP field has been provided series. For two new ESP field installation 2.99crore rupees and running cost will be extra 1.43lakh rupees per month. After installation of two new fields stack emission reduced to 27 mg/Nm3(March2023 month average) from 41 mg/Nm3 (March2022 month average). Increase of two ESP fields had drastically decrease stack emission as well as it reduces the shutdown of boiler due to one or two field failure which increases the production.
Keywords:
ESP(Electrostatic Precipitator), Stack Emission, TPH(Ton per Hour)
Cite Article:
"COMPARATIVE FEASIBILITY STUDIES OF ESP IN POWER SECTOR “A CASE STUDY", International Journal of Novel Research and Development (www.ijnrd.org), ISSN:2456-4184, Vol.8, Issue 8, page no.e121-e131, August-2023, Available :http://www.ijnrd.org/papers/IJNRD2308412.pdf
Downloads:
000118754
ISSN:
2456-4184 | IMPACT FACTOR: 8.76 Calculated By Google Scholar| ESTD YEAR: 2016
An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 8.76 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator
Facebook Twitter Instagram LinkedIn